ArtÃÂculo Original
Resultados clÃÂnicos en el implante telescopado de stents convencionales y farmacoactivos: impacto del uso mixto Vs. exclusivo de stents farmacoactivos
Gerardo Nau, Mariano Albertal, Fernando Cura, Lucio Padilla, Alfonsina Candiello, Jorge Belardi
Revista Argentina de CardioangiologÃÂa Intervencionista 2011;(1): 0020-0024 | Doi: 10.30567/RACI/20111/0020-0024
Texto completo solo disponible en PDFIntroducción: El implante telescopado (IT) de stent farmacoactivos (SFA) en lesiones largas ha demostrado ser eficaz; sin embargo se desconoce el impacto clínico del IT de tipo mixto [combinación de SFA y stent convencional (SC)].
Objetivo: evaluar los resultados clínicos en pacientes sometidos a IT acorde al tipo de stent utilizado.
Métodos: incluimos de forma consecutiva pacientes sometidos a IT durante los años 2004-2008. Se dividió a la población según el tipo de stent utilizado (Grupo “E”: exclusivmente SFA, Grupo “M”: SFA + SC y Grupo “SC”: solo SC) evaluándose los resultados clínicos de cada uno de los grupos. El seguimiento clínico fue de 572 días (intercuartilos 25-75: 259-1012 días).
Resultados: 463 pacientes fueron sometidos a IT (Grupo E 26.6%, grupo M 16.6% y Grupo SC 56.8%). Los pacientes incluidos en el grupo M fueron más jóvenes (Grupo E 67,3±10.7; Grupo M 62.9±10.1; Grupo SC 66.5±11.9; p<0.05) y los pertenecientes al grupo SC fueron intervenidos en forma más frecuente por síndromes coronarios agudos (Grupo E 17,1%; Grupo M 16,9%; Grupo SC 29,7% ; p<0.05). Es importante destacar la mayor utilización de una estrategia mixta en pacientes sometidos a angioplastia de múltiples vasos (Grupo E 22,8%; Grupo M 37,7%; Grupo SC 22,1%; p<0.05). No se evidenciaron diferencias en cuanto a la mortalidad y la trombosis a 30 días. El grupo E se asoció a una menor tasa de eventos cardiacos mayores (ECM) (Grupo E 4,1%; Grupo M 11,7%; Grupo SC 11%, p<0.05). El análisis logístico multivariado identificó al grupo E (OR 0,27; IC 95% 0,10-0,70; p=0,008) y a la longitud del segmento que recibió el IT de stents (OR 1,03; IC 95%1,01-1,05; p=0,01) como predictores independientes de ECM.
Conclusiones: a) el IT con SFA exclusivo resultó seguro y eficaz) b) la longitud del segmento que recibió IT de stents continúa siendo una variable independiente de eventos cardíacos, independientemente de la estrategia utilizada.
Palabras clave: enfermedad coronaria, lesiones largas, stent, implante telescopado.
Background: Effective coverage of long coronary lesions usually requires stent overlap (SO). The clinical impact of hybrid stents (drug-eluting stent + bare metal stent) during SO is currently unknown. Objective: Evaluate the clinical outcome of SO according to stent use. Methods: We included all patients treated with SO during 2004-2008 and classified them according to the SO strategy: Group E exclusive DES, Group H, DES plus bare-metal stent (BMS)] or Group BMS. Follow-up data was available in 92% (median 572 days, interquartiles 25-75%: 259-1012 days). Results: From 463 patients, 26.6% received only DES, 16.6% were H and 56.8% BMS. Patients included in M group were younger (Group E 67,3±10.7; Group H 62.9±10.1; Group BMS 66.5±11.9; p<0.05), and patients included in BMS group had significantly more acute coronary syndromes (Group E 17,1; Group H 16,9; Group BMS 29,7 ; p<0.05). Also, a hybrid strategy was used more frequently in the treatment of patients undergoing multiple vessel angioplasty. (Group E 22,8; Group H 37,7; Group BMS 22,1; p<0.05). There were no differences in mortality and stent thrombosis, related to the strategy used. Even though, mayor cardiac events were significantly lower when an exclusive DES strategy was used (Group E 4,1; Group H 11,7; Group BMS 11 ; p<0.05). Multivariate analysis identified DES exclusive strategy (OR 0,27; IC 95% 0,10-0,70; p=0,008) and stent length (OR 1,03; IC 95%1,01-1,05; p=0,01) as independent predictors of mayor cardiac events. Conclusion: a) an exclusive DES strategy was clinically superior to both H and BMS; b) overall, in the whole population, a longer SO was linked with a greater rate of thrombosis and/or target lesion revascularization.
Keywords: long lesion; stents; coronary artery stenosis; coronary disease.
Los autores declaran no poseer conflictos de intereses.
Fuente de información Colegio Argentino de Cardioangiólogos Intervencionistas. Para solicitudes de reimpresión a Revista Argentina de CardioangiologÃa intervencionista hacer click aquÃ.
Recibido | Aceptado | Publicado 2011-04-01
Esta obra está bajo una Licencia Creative Commons Atribución-NoComercial-SinDerivar 4.0 Internacional.
Este artÃculo no contiene material bibliografico
Para descargar el PDF del artÃculo
Resultados clÃÂnicos en el implante telescopado de stents convencionales y farmacoactivos: impacto del uso mixto Vs. exclusivo de stents farmacoactivos
Haga click aquÃ
Revista Argentina de CardioangiologÃa intervencionista
Número 1 | Volumen
1 | Año 2011
Exposición ocupacional de las pr...
Eliseo Vañó
Grupo WIN (Women in Innovations)
Liliana Grinfeld
Consenso de la Society for Cardiac ...
Patricia Best y cols.
Resultados clÃÂnicos en el implan...
Gerardo Nau y cols.
Protección radiológica en Car...
Ariel Durán
Adaptación de la técnica ââ‚...
Alejandro Goldsmit y cols.
Trombo en vena cava inferior. Util...
orge G AllÃÂn y cols.
Discinesia apical transitoria
Gustavo Leiva
Etiquetas
enfermedad coronaria, lesiones largas, stent, implante telescopado
Tags
long lesion; stents; coronary artery stenosis; coronary disease
Colegio Argentino de Cardioangiólogos Intervencionistas
Viamonte 2146 6° (C1056ABH) Ciudad Autónoma de Buenos Aires | Argentina | tel./fax +54 11 4952-2117 / 4953-7310 |e-mail revista@caci.org.ar | www.caci.org.ar
Revista Argentina de CardioangiologÃÂa Intervencionista | ISSN 2250-7531 | ISSN digital 2313-9307
La plataforma Meducatium es un proyecto editorial de Publicaciones Latinoamericanas S.R.L.
Piedras 1333 2° C (C1240ABC) Ciudad Autónoma de Buenos Aires | Argentina | tel./fax +54 11 5217-0292 | e-mail info@publat.com.ar | www.publat.com.ar
Meducatium versión
2.2.2.4 ST